DOWNLOAD BROCHURE

Proco Pen-Seal

The Proco Pen-Seal is designed to provide a gas and water-tight seal. All sizes have been tested to withstand a hydrostatic seal up to 20 psig or 40 feet of head pressure, in addition to withstanding temperatures up to 250 °F.

The Pen-Seal’s standard elastomer material is EPDM, but a Nitrile material is available if the seal may come in contact with hydrocarbons, oil, gas, jet fuel, or miscellaneous solvents.

The Pen-Seal utilizes glass-reinforced plastic, and all hardware is manufactured from steel zinc dichromate. For corrosion resistance, 316 stainless steel hardware is available.

For more information about the features and benefits of the Proco Pen-Seal, download our brochure:

For up-to-date pricing and availability information, contact PROCO today.

Pipe Penetration Seal

 

Table 1Standard Weight Steel or PVC Pipe Sleeve1Cast or Core Bit Drilled Hole1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
0.50.8402.0002.067PS-20042.000PS-2004
0.751.0502.5002.469PS-27562.500PS-2756
11.3152.5002.469PS-20053.000PS-3154
1.251.6603.0003.068PS-27583.000PS-2758
1.51.9003.0003.068PS-20073.500PS-3005
22.3753.5003.548PS-20084.000PS-3006
2.52.8754.0004.026PS-20094.000PS-2009
33.5005.0005.047PS-30085.000PS-3008
3.54.0006.0006.065PS-315106.000PS-31510
44.5006.0006.065PS-300106.000PS-30010
55.5638.0007.981PS-340138.000PS-34013
66.62510.00010.020PS-4751010.000PS-47510
88.62512.00012.000PS-4751212.000PS-47512
1010.75014.00013.250PS-4251014.000PS-47514
1212.75016.00015.250PS-4251216.000PS-47517
1414.00018.00017.250PS-4751818.000PS-57516
1616.00020.00019.250PS-4752120.000PS-57518
1818.00022.00021.250PS-4752322.000PS-57520
2020.00024.00023.250PS-4752524.000PS-57522
2222.00026.00025.250PS-4752826.000PS-57524
2424.00028.00027.250PS-4753028.000PS-57526
2626.00030.00029.250PS-4753330.000PS-57528
2828.00032.00031.250PS-4753532.000PS-57530
3030.00034.00033.250PS-4753734.000PS-57532
3232.00036.00035.250PS-4754036.000PS-57534
3434.00040.00039.250PS-5002938.000PS-57536
3636.00042.00041.250PS-5003140.000PS-57538
4242.00048.00047.250PS-5003646.000PS-57544
4848.00054.00053.250PS-5004152.000PS-57550

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for PEN-SEAL Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. PEN-SEAL sets are sold in belts of ten (10) links.

 

Table 2Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL
PIPE SIZE
(Inches)

ACTUAL
PIPE O.D.
(Inches)

SLEEVE
NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
22.5003.5003.548PS-20084.000PS-3006
2.252.7505.0005.047PS-34075.000PS-3407
33.9606.0006.065PS-315106.000PS-31510
44.8008.0007.981PS-41078.000PS-4107
66.90012.00010.020PS-4101010.000PS-41010
89.05012.00012.000PS-400912.000PS-4009
1011.10014.00013.250PS-3402414.000PS-40010
1213.20016.00015.250PS-3251416.000PS-36021
1415.30018.00017.250PS-3251618.000PS-36024
1617.40020.00019.250PS-3153920.000PS-36027
1819.50024.00023.250PS-4752524.000PS-52517
2021.60026.00025.250PS-4752826.000PS-52519
2425.80030.00029.250PS-4753229.000PS-41033
3032.00036.00035.250PS-4754035.000PS-40029
3638.30042.00041.250PS-4003441.000PS-36059
4244.50050.00049.250PS-5003848.000PS-47555
4850.80054.00053.250PS-4254554.000PS-41063

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal sets are sold in belts of ten (10) links.

Table 3Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
0.50.6252.0002.067PS-27542.000PS-2754
0.750.8752.0002.067PS-20042.000PS-2004
11.1252.5002.469PS-27563.000PS-3154
1.251.3752.5002.469PS-20053.000PS-3004
1.51.6253.0003.068PS-27583.000PS-2758
22.1253.5003.548PS-30053.500PS-2759
2.52.6254.0004.026PS-275114.000PS-27511
33.1255.0005.047PS-31585.000PS-315
44.1256.0006.065PS-315106.000PS-31510
66.1258.0007.981PS-315158.000PS-31515
88.12510.00010.020PS-325912.000PS-57510
1010.12514.00013.250PS-4101414.000PS-57512
1212.12516.00015.250PS-4101616.000PS-57514
 
 
Table 4Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
22.3803.5003.548PS-20084.000PS-3006
33.5005.0005.047PS-30085.000PS-3008
44.5006.0006.065PS-300106.000PS-30010
55.5008.0007.981PS-340138.000PS-34013
66.50010.00010.020PS-475910.000PS-4759
88.62012.00012.000PS-4751212.000PS-47512
1010.75014.00013.250PS-4251014.000PS-47514
1212.75016.00015.250PS-4251216.000PS-47517 
1515.88020.00019.250PS-4752118.000PS-34033

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal sets are sold in belts of ten (10) links.

Table 5Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
22.3004.0004.026PS-31564.000PS-3156
33.3005.0005.047PS-31595.000PS-3158
44.3006.0006.065PS-315116.000PS-31511
55.3008.0007.981PS-360108.000PS-36010
66.3008.0007.981PS-315158.000PS-31515
88.38012.00012.000PS-4751212.000PS-47512
1010.50014.00013.250PS-3601714.000PS-47514
1212.50016.00015.250PS-3602016.000PS-47517 
1515.62020.00019.250PS-4752018.000PS-42514

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal sets are sold in belts of ten (10) links.

Table 6Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.

(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
0.50.7062.0002.067PS-27542.000PS-2754
0.750.9222.0002.067PS-20042.000PS-2004
11.1632.5002.469PS-27563.000PS-3154
1.251.5103.0003.068PS-27573.000PS-2757
1.51.7403.5003.548PS-31553.500PS-3155
22.1973.5003.548PS-275104.000PS-3156
2.52.8754.0004.026PS-20094.000PS-2009
33.5005.0005.047PS-30085.000PS-3008
44.5006.0006.065PS-300106.000PS-30010

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal sets are sold in belts of ten (10) links.

Table 7Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
0.50.8152.0002.067PS-20042.000PS-2004
0.751.0292.0002.067PS-20042.500PS-2756
11.2902.5002.469PS-27563.000PS-3004
1.251.6383.5003.548PS-31553.000PS-2757
1.51.8833.5003.548PS-30053.500PS-3005
22.3604.0004.026PS-30064.000PS-3006
2.52.8574.0004.026PS-20094.000PS-2009
33.4765.0005.047PS-30085.000PS-3008
3.53.9716.0006.065PS-32556.000PS-3255
44.4666.0006.065PS-300106.000PS-30010

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal  Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal  sets are sold in belts of ten (10) links.

Table 8Standard Weight Steel or PVC Pipe Sleeve 1Cast or Core Bit Drilled Hole 1

NOMINAL PIPE SIZE
(Inches)

ACTUAL PIPE O.D.
(Inches)

SLEEVE NOMINAL PIPE SIZE
(Inches)

SLEEVE ACTUAL I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS

HOLE I.D.
(Inches)

PEN-SEAL PART NUMBERREQUIRED NUMBER OF LINKS
0.50.8402.0002.067PS-20042.000PS-2004
0.751.0502.5002.469PS-27562.500PS-2756
11.3152.5002.469PS-20053.000PS-3004
1.251.6603.5003.548PS-31553.000PS-2757
1.51.9003.5003.548PS-30053.500PS-2005
22.3754.0004.026PS-30064.000PS-3006
2.52.8754.0004.026PS-20094.000PS-2009
33.5005.0005.047PS-30085.000PS-300
3.54.0006.0006.065PS-32556.000PS-3255
44.5006.0006.065PS-300106.000PS-30010
55.5638.0007.981PS-42568.000PS-4256
66.6258.0007.981PS-3001510.000PS-47510

NOTES:
1. Minimum recommended sleeve length or wall thickness is 4” for Pen-Seal Model PS-325 and smaller and 6” for Models PS-400 and larger.
2. Pen-Seal sets are sold in belts of ten (10) links.

 

SEALING RANGE
SIZE

NEUTRAL STATE THICKNESS
(Inches)

EXPANDED STATE THICKNESS
(Inches)

CHORD LENGTH
(Inches)

2000.5000.6201.125
2750.6200.8000.910
3000.7100.9201.510
3150.8201.1001.470
3250.9401.1403.100
3401.0501.3301.570
3601.2901.6502.106
4001.4301.8703.625
4101.4801.9102.600
4251.1301.4303.625
4751.6202.0802.625
5002.3702.8103.860
5252.1802.5803.860
5751.8802.3503.100
6003.2004.0006.000

 

Please Note: Pen-Seal sets are sold in belts of ten (10) links.

Materials Guide
TYPESEAL MATERIALPRESSURE PLATESBOLTS & NUTSTEMPERATURE RANGE (˚F)APPLICATIONS
EEPDM BlackGLASS REINFORCED PLASTICSTEEL Zinc Dichromate-40˚ to +250˚Suitable for most application in water, above ground and direct burial. Provides electrical insulation where cathodic protection is required.
ESEPDM BlackGLASS REINFORCED PLASTICSTAINLESS STEEL (316)-40˚ to +250˚Suitable for environments where the corrosion resistance of stainless steel hardware is required.
PNITRILEGLASS REINFORCED PLASTICSTEEL Zinc Dichromate-40˚ to +210˚Resistant to most hydrocarbons, oil, gas, jet fuel, and many solvents.
PSNITRILEGLASS REINFORCED PLASTICSTAINLESS STEEL (316)-40˚ to +210˚Same as above, but with corrosion resistance of stainless steel hardware.
KSILICONESTEEL Zinc DichromateSTEEL Zinc Dichromate-40˚ to +400˚High temperature applications.

Standard steel wall sleeves are positioned in the wall before the concrete is poured. Wall sleeves offer a cleaner installation for every engineered piping system.